Condition or disease | Intervention/treatment | Phase |
---|---|---|
Chest Pain Cough Thoracic Diseases Lung Diseases | Diagnostic Test: ULDCT | Not Applicable |
Study Type : | Interventional (Clinical Trial) |
Actual Enrollment : | 295 participants |
Allocation: | Randomized |
Intervention Model: | Parallel Assignment |
Masking: | None (Open Label) |
Primary Purpose: | Diagnostic |
Official Title: | Accuracy of Ultra-Low-Dose-CT (ULDCT) of the Chest Compared to Plain Film in an Unfiltered Emergency Department Patient Cohort |
Actual Study Start Date : | May 2, 2019 |
Actual Primary Completion Date : | November 26, 2019 |
Actual Study Completion Date : | November 26, 2019 |
Arm | Intervention/treatment |
---|---|
Reporting order: Plain Film - ULDCT
The plain film of half the participants (randomized) will be submitted for reporting by a radiologist as a first imaging method. After finishing this report, the same radiologist will assess the ULDCT of this participant. In this second report, the findings of both examinations will be summarized, and a second report will be filed. Emergency physicians will first receive the report for the plain film of the chest and will be asked for the diagnosis and its probability. Next, the report for ULDCT will be presented to them. Again, diagnosis and probabilities will be documented. |
Diagnostic Test: ULDCT
Ultra-Low-Dose-CT (ULDCT) of the chest using tin filters with third-generation dual-energy CT devices. The projected dose used will be approximately 0.2 mSv per ULDCT of the chest.
|
Reporting order: ULDCT - Plain Film
For half the participants (randomized) radiologists will first receive the data from ULDCT of the chest and write a report. Subsequently, they will receive the data from the plain film of the chest and may expand their report (explicitly separated). Emergency physicians will first receive the report for the ULDCT of the chest and will be asked for probabilities of the nine most frequent diagnoses in chest-imaging plus "other". Next, they will be presented with the report for the plain film and will again be asked to give an estimation of the probabilities for the same diagnoses as before. |
Diagnostic Test: ULDCT
Ultra-Low-Dose-CT (ULDCT) of the chest using tin filters with third-generation dual-energy CT devices. The projected dose used will be approximately 0.2 mSv per ULDCT of the chest.
|
Initial radiologic diagnostic accuracy of both methods will be assessed by analyzing the number of reports that are changed after the images of the second modality become available to the radiologist in Arm 1 compared to Arm 2.
In a final approach, the diagnostic accuracy will be analyzed by retrospectively comparing all reports with the gold standard, which will be built from all available patient data at the end of the study, including all follow-up imaging studies and laboratory tests.
Ages Eligible for Study: | 18 Years to 92 Years (Adult, Older Adult) |
Sexes Eligible for Study: | All |
Accepts Healthy Volunteers: | No |
Inclusion Criteria:
Exclusion Criteria:
Austria | |
Vienna General Hospital - Medical University of Vienna | |
Vienna, Austria, 1090 |
Principal Investigator: | Helmut Ringl, MD | Medical University of Vienna |
Tracking Information | |||||
---|---|---|---|---|---|
First Submitted Date ICMJE | April 17, 2019 | ||||
First Posted Date ICMJE | April 22, 2019 | ||||
Last Update Posted Date | December 19, 2019 | ||||
Actual Study Start Date ICMJE | May 2, 2019 | ||||
Actual Primary Completion Date | November 26, 2019 (Final data collection date for primary outcome measure) | ||||
Current Primary Outcome Measures ICMJE |
Accuracy of ultra-low-dose-CT of the chest and plain film of the chest [ Time Frame: 1 year ] Initial radiologic diagnostic accuracy of both methods will be assessed by analyzing the number of reports that are changed after the images of the second modality become available to the radiologist in Arm 1 compared to Arm 2.
In a final approach, the diagnostic accuracy will be analyzed by retrospectively comparing all reports with the gold standard, which will be built from all available patient data at the end of the study, including all follow-up imaging studies and laboratory tests.
|
||||
Original Primary Outcome Measures ICMJE | Same as current | ||||
Change History | |||||
Current Secondary Outcome Measures ICMJE |
|
||||
Original Secondary Outcome Measures ICMJE | Same as current | ||||
Current Other Pre-specified Outcome Measures | Not Provided | ||||
Original Other Pre-specified Outcome Measures | Not Provided | ||||
Descriptive Information | |||||
Brief Title ICMJE | Accuracy of Ultra-Low-Dose-CT of the Chest Compared to Plain Film in an Unfiltered Emergency Department Patient Cohort | ||||
Official Title ICMJE | Accuracy of Ultra-Low-Dose-CT (ULDCT) of the Chest Compared to Plain Film in an Unfiltered Emergency Department Patient Cohort | ||||
Brief Summary | This trial compares the accuracy provided by plain film as well as ultra-low-dose-computed-tomography (ULDCT) of the chest. It also aims to analyze differences in diagnostic confidence and therapeutic consequence offered by these two imaging modalities. | ||||
Detailed Description |
For nearly a century, chest X-ray (plain film, projectional radiography) has been the established primary imaging modality for patients with acute chest pain, suspected pneumonia, and / or acute dyspnoea in the diagnostic pathway of emergency departments, although the sensitivity and specificity of this X-ray technique are moderate. The widespread availability and use of chest X-ray is due to the low acquisition and operating costs for projectional radiography equipment, the short examination time, and the very low radiation exposure. In addition, projectional radiography of the chest often serves as a guide for further, more sensitive, diagnostical procedures. However, these advantages are partially offset by the disadvantages inherent to projectional methods: anatomical structures may superpose or mask pathological structures. As a result, some areas of the lung may be obscured, and assessment may therefore be limited. Whereas computed tomography was reserved for certain clinical questions over the last few decades, and, in most cases, served as a second imaging approach after plain film radiography, it has increasingly evolved as a primary imaging modality for several indications (e.g., suspicion of pulmonary embolism, highly suspected aortic dissection). This rise of computed tomography was due not only to its significant advantage of no superposition, but also partly driven by the marked reduction in radiation dose needed without sacrificing image quality. This was driven by the development of new detectors, modulation of tube current and voltage, as well as iterative reconstruction techniques. As a result, recent computed tomography scanners currently offer not only a more precise visualization of differences in tissue-attenuation and the significant advantage of the absence of artefacts due to superposition, but also allow for imaging with a considerably reduced radiation dosage compared to older scanners. Therefore, computed tomography may now be utilized as screening method in specific indications that carry an increased risk of certain pathologies (e.g., in long-time smokers). The introduction of the latest generation of computed tomography devices about three years ago allowed for an even further reduction in dose by filtering out low-energy photons using a tin filter, which offers the possibility of a reduction in radiation dose by another 50 % or more for established CT indications. For specific indications (e.g., lung nodules in follow-up), the radiation dose may even be reduced to a tenth or one-hundredth of a standard-dose CT (SDCT). The current reference dose-length-product (DLP) in Germany for thoracic standard-dose CT (SDCT) is ~350 mGycm (effective dose ~6 mSv) and, for thoracic low-dose-CT (LDCT / HR-CT), ~100 mGycm (effective dose ~1.7 mSv). However, the latest devices (third-generation dual-energy CT) provide the opportunity to considerably reduce the reference dose of thoracic low-dose CT. In the current literature, these scans are referred to as Ultra-Low-Dose-CT (ULDCT) and are usually associated with a radiation dosage of 0.14 to 0.5 mSv. For this dose range, no standardized reference values have been published as yet. The limiting factors of ULDCT are quantum noise, loss of spatial resolution, and other image artefacts. Therefore, careful selection of appropriate CT protocols and dosage is mandatory in order to achieve sufficient image quality to answer the respective diagnostic question. Several papers have been published on the subject of ULDCT, which are dedicated to the comparison of ULDCT with LDCT and/or SDCT. These papers conclude that this technology may be used with sufficient sensitivity and specificity for indications such as dyspnea, emphysema, or lung nodules. Due to the potential to reduce the radiation dose to less than 1/30 of a standard-dose CT while still providing acceptable image quality with the latest generation of devices, ULDCT of the chest is emerging as an interesting alternative to conventional chest X-ray. To the best of the authors' knowledge, there are currently no studies comparing and evaluating ultra-low-dose-CT as a primary imaging alternative to chest X-ray in emergency department patients. This study aims to compare ULDCT and plain film of the chest with regard to their accuracy in an unfiltered patient cohort of an emergency department. For this purpose, the investigator's ULDCT protocol will use the lowest possible dose at which image quality is diagnostically sufficient (approximately 0.2 mSv effective dose). This corresponds to less than 1/30 of the radiation dose of a standard-dose CT of the chest and to only about 2.5 times the dose of a chest X-ray in two views. This dose is equal to less than a month of natural background radiation in Austria and less than the radiation exposure on an intercontinental flight. In addition to the accuracy of ULDCT of the chest compared to plain film of the chest, this trial also aims to analyze the clinical relevance of both methods by assessing the respective impact on final diagnosis, as well as possible changes in therapy. |
||||
Study Type ICMJE | Interventional | ||||
Study Phase ICMJE | Not Applicable | ||||
Study Design ICMJE | Allocation: Randomized Intervention Model: Parallel Assignment Masking: None (Open Label) Primary Purpose: Diagnostic |
||||
Condition ICMJE |
|
||||
Intervention ICMJE | Diagnostic Test: ULDCT
Ultra-Low-Dose-CT (ULDCT) of the chest using tin filters with third-generation dual-energy CT devices. The projected dose used will be approximately 0.2 mSv per ULDCT of the chest.
|
||||
Study Arms ICMJE |
|
||||
Publications * |
|
||||
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||
Recruitment Information | |||||
Recruitment Status ICMJE | Completed | ||||
Actual Enrollment ICMJE |
295 | ||||
Original Estimated Enrollment ICMJE |
250 | ||||
Actual Study Completion Date ICMJE | November 26, 2019 | ||||
Actual Primary Completion Date | November 26, 2019 (Final data collection date for primary outcome measure) | ||||
Eligibility Criteria ICMJE |
Inclusion Criteria:
Exclusion Criteria:
|
||||
Sex/Gender ICMJE |
|
||||
Ages ICMJE | 18 Years to 92 Years (Adult, Older Adult) | ||||
Accepts Healthy Volunteers ICMJE | No | ||||
Contacts ICMJE | Contact information is only displayed when the study is recruiting subjects | ||||
Listed Location Countries ICMJE | Austria | ||||
Removed Location Countries | |||||
Administrative Information | |||||
NCT Number ICMJE | NCT03922516 | ||||
Other Study ID Numbers ICMJE | EK-Nr. 2254/2018 | ||||
Has Data Monitoring Committee | Not Provided | ||||
U.S. FDA-regulated Product |
|
||||
IPD Sharing Statement ICMJE |
|
||||
Responsible Party | Prof Helmut Ringl, MD, Medical University of Vienna | ||||
Study Sponsor ICMJE | Medical University of Vienna | ||||
Collaborators ICMJE | Siemens AG | ||||
Investigators ICMJE |
|
||||
PRS Account | Medical University of Vienna | ||||
Verification Date | December 2019 | ||||
ICMJE Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP |