The TRANSLUMINA GmbH YuChooSeR Observatory is a prospective, multicentric post-marketing observatory designed to evaluate large scale safety and reliability of the Yukon Choice PC and the Yukon Chrome PC stents systems use in routine, clinical practice.
This based observatory will enroll 2000 patients from 14 to 30 sites in France.
Condition or disease | Intervention/treatment |
---|---|
Coronaropathy | Device: Yukon Choice PC and Yukon Chrome PC |
TRANSLUMINA GmbH has launched clinical programs to demonstrate the safety and efficacy of its technology.
The Translumina Yukon Choice PC drug-eluting stent, coated with Rapamycin (Sirolimus) and the biodegradable component polylactide (PLA), has an excellent history of pre-clinical and clinical results.
The Yukon Chrome PC has the identical coating technique and coating properties (dosage, thickness) like the clinically proven Yukon Choice PC.
In two independent trials ISAR-TEST 3 and ISAR-TEST 4 the Yukon DES platform showed angiographic and clinical equivalence with the Cypher stent after 1 year and 3 years of follow-up.
Latest clinical data, published by G.Stefanini et al, show the excellent long-term outcome of the Yukon biodegradable polymer DES technology in a meta-analysis, comparing the clinical outcome after 4 years in more than 4000 patients with the Cypher stent. This analysis shows for the first time that the definite Very Late Stent Thrombosis (VLST) can be reduced statistically significant by using the biodegradable PLA polymer coating technology of the Yukon DES.
An additional sub-group analysis shows also benefit in difficult patient groups like diabetics and patients with acute myocardial infarkt.
Due to this excellent clinical outcome the Yukon DES technology is recommended by the latest ESC guidelines for myocardial revascularization.
The final 5 years long-term clinical follow-up of the ISAR-TEST 4 randomized controlled clinical trial showed excellent safety and efficacy data for the Yukon DES when compared with the Cypher and Xience V stent. The definite and probable stent thrombosis was only 1,2% for the Yukon compared to 1,4% and 2,4% for the 2 permanent polymer coated competitor DES.
In a continued approach to collect safety and efficiency data on its products, TRANSLUMINA GmbH is determined to collect safety and efficiency information at a very large scale. Based on all this, the Yukon Choice PC & the Yukon Chrome PC stents have been designed to treat coronary arteries in a relatively easy and simple-to-achieve manner, while providing a higher level of clinical efficacy.
Additionally, the Observatory is aimed to provide a learning tool that will help to define best practices/techniques as all results will be fed back to participants and to a larger audience through publications.
In this Observatory, analyses will be performed per clinical presentation and per stent type.
Study Type : | Observational |
Estimated Enrollment : | 2000 participants |
Observational Model: | Cohort |
Time Perspective: | Prospective |
Official Title: | Multicenter Observatory to Assess the Yukon Choice PC & the Yukon Chrome PC Sirolimus Eluting Bioabsorbable Polymer Stents Systems in Routine Clinical Practice |
Actual Study Start Date : | April 17, 2019 |
Estimated Primary Completion Date : | April 24, 2022 |
Estimated Study Completion Date : | April 17, 2023 |
Tracking Information | |||||||||
---|---|---|---|---|---|---|---|---|---|
First Submitted Date | April 12, 2019 | ||||||||
First Posted Date | April 17, 2019 | ||||||||
Last Update Posted Date | October 8, 2020 | ||||||||
Actual Study Start Date | April 17, 2019 | ||||||||
Estimated Primary Completion Date | April 24, 2022 (Final data collection date for primary outcome measure) | ||||||||
Current Primary Outcome Measures |
The primary endpoint is Target Lesion Failure (TLF) rate at 12 months follow-up [ Time Frame: 12 months follow-up ] Target Lesion Failure (TLF) is defined as the composite of cardiac death, target-vessel myocardial Infarction and clinically indicated target lesion revascularization (TLR) by percutaneous or surgical methods.
|
||||||||
Original Primary Outcome Measures | Same as current | ||||||||
Change History | |||||||||
Current Secondary Outcome Measures |
|
||||||||
Original Secondary Outcome Measures | Same as current | ||||||||
Current Other Pre-specified Outcome Measures | Not Provided | ||||||||
Original Other Pre-specified Outcome Measures | Not Provided | ||||||||
Descriptive Information | |||||||||
Brief Title | Observatory to Assess the Yukon Choice PC & the Yukon Chrome PC Sirolimus Eluting Bioabsorbable Polymer Stents Systems | ||||||||
Official Title | Multicenter Observatory to Assess the Yukon Choice PC & the Yukon Chrome PC Sirolimus Eluting Bioabsorbable Polymer Stents Systems in Routine Clinical Practice | ||||||||
Brief Summary |
The TRANSLUMINA GmbH YuChooSeR Observatory is a prospective, multicentric post-marketing observatory designed to evaluate large scale safety and reliability of the Yukon Choice PC and the Yukon Chrome PC stents systems use in routine, clinical practice. This based observatory will enroll 2000 patients from 14 to 30 sites in France. |
||||||||
Detailed Description |
TRANSLUMINA GmbH has launched clinical programs to demonstrate the safety and efficacy of its technology. The Translumina Yukon Choice PC drug-eluting stent, coated with Rapamycin (Sirolimus) and the biodegradable component polylactide (PLA), has an excellent history of pre-clinical and clinical results. The Yukon Chrome PC has the identical coating technique and coating properties (dosage, thickness) like the clinically proven Yukon Choice PC. In two independent trials ISAR-TEST 3 and ISAR-TEST 4 the Yukon DES platform showed angiographic and clinical equivalence with the Cypher stent after 1 year and 3 years of follow-up. Latest clinical data, published by G.Stefanini et al, show the excellent long-term outcome of the Yukon biodegradable polymer DES technology in a meta-analysis, comparing the clinical outcome after 4 years in more than 4000 patients with the Cypher stent. This analysis shows for the first time that the definite Very Late Stent Thrombosis (VLST) can be reduced statistically significant by using the biodegradable PLA polymer coating technology of the Yukon DES. An additional sub-group analysis shows also benefit in difficult patient groups like diabetics and patients with acute myocardial infarkt. Due to this excellent clinical outcome the Yukon DES technology is recommended by the latest ESC guidelines for myocardial revascularization. The final 5 years long-term clinical follow-up of the ISAR-TEST 4 randomized controlled clinical trial showed excellent safety and efficacy data for the Yukon DES when compared with the Cypher and Xience V stent. The definite and probable stent thrombosis was only 1,2% for the Yukon compared to 1,4% and 2,4% for the 2 permanent polymer coated competitor DES. In a continued approach to collect safety and efficiency data on its products, TRANSLUMINA GmbH is determined to collect safety and efficiency information at a very large scale. Based on all this, the Yukon Choice PC & the Yukon Chrome PC stents have been designed to treat coronary arteries in a relatively easy and simple-to-achieve manner, while providing a higher level of clinical efficacy. Additionally, the Observatory is aimed to provide a learning tool that will help to define best practices/techniques as all results will be fed back to participants and to a larger audience through publications. In this Observatory, analyses will be performed per clinical presentation and per stent type. |
||||||||
Study Type | Observational | ||||||||
Study Design | Observational Model: Cohort Time Perspective: Prospective |
||||||||
Target Follow-Up Duration | Not Provided | ||||||||
Biospecimen | Not Provided | ||||||||
Sampling Method | Non-Probability Sample | ||||||||
Study Population | Patients with symptomatic ischemic heart disease requiring stenting. All patients selected by the investigator to receive a Yukon Choice PC and/or a Yukon Chrome PC stent can be enrolled. Patient must be over 18 years old and be informed verbally and in writing about the nature and aim of the study. | ||||||||
Condition | Coronaropathy | ||||||||
Intervention | Device: Yukon Choice PC and Yukon Chrome PC
The Yukon Choice PC & the Yukon Chrome PC Sirolimus Eluting Bioabsorbable Polymer Coronary Stent Systems are indicated for improving coronary luminal diameter in patients with symptomatic ischemic heart disease.
|
||||||||
Study Groups/Cohorts | Not Provided | ||||||||
Publications * | Not Provided | ||||||||
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||||||
Recruitment Information | |||||||||
Recruitment Status | Recruiting | ||||||||
Estimated Enrollment |
2000 | ||||||||
Original Estimated Enrollment | Same as current | ||||||||
Estimated Study Completion Date | April 17, 2023 | ||||||||
Estimated Primary Completion Date | April 24, 2022 (Final data collection date for primary outcome measure) | ||||||||
Eligibility Criteria |
Inclusion Criteria:
Exclusion Criteria:
|
||||||||
Sex/Gender |
|
||||||||
Ages | 18 Years and older (Adult, Older Adult) | ||||||||
Accepts Healthy Volunteers | No | ||||||||
Contacts |
|
||||||||
Listed Location Countries | France | ||||||||
Removed Location Countries | |||||||||
Administrative Information | |||||||||
NCT Number | NCT03918070 | ||||||||
Other Study ID Numbers | 2018-A03455-50 | ||||||||
Has Data Monitoring Committee | No | ||||||||
U.S. FDA-regulated Product |
|
||||||||
IPD Sharing Statement |
|
||||||||
Responsible Party | Translumina GmbH | ||||||||
Study Sponsor | Translumina GmbH | ||||||||
Collaborators | EVAMED | ||||||||
Investigators |
|
||||||||
PRS Account | Translumina GmbH | ||||||||
Verification Date | October 2020 |